Chemiluminescence Nitrogen Analyzer for Solid Liquid Gas Samples 0.1-10000mg/L

Plaats van herkomst China
Merknaam Shandong Shengtai Instrument Co., Ltd.
Certificering SH/T 0657 ASTM D5762-2017 SH/T0704 ASTM D4629 GB/T 17674
Modelnummer SH708
Min. bestelaantal 1
Verpakking Details Houten behuizing
Levertijd 7-15 werkdagen
Betalingscondities t/t
Levering vermogen 10000 stuks/jaar

Contacteer me voor vrije steekproeven en coupons.

WhatsApp:0086 18588475571

wechatten: 0086 18588475571

Skypen: sales10@aixton.com

Als u om het even welke zorg hebt, verstrekken wij de online-Help van 24 uur.

x
Productdetails
Basisparameters Soorten monsters: vloeistof, vast en gas Meetmethode chemiluminescentiemethode
Meetbereik 0.1-10000 mg/l Temperatuursysteem Kamertemperatuur 1050 °C
Temperatuurregeling ± 3 ℃ Grootte van de host 305 (W) × 460 (D) × 440 (H) mm
Markeren

chemiluminescence nitrogen analyzer for solids

,

nitrogen analyzer for liquid samples

,

gas sample nitrogen analyzer 0.1-10000mg/L

Laat een bericht achter
Productomschrijving

SH708 Chemiluminescence nitrogen analyzer

The SH708 chemiluminescence nitrogen analyzer uses chemiluminescence method to determine the total nitrogen content, which improves the ability to resist impurity interference, avoids the complicated operation of the titration cell caused by the electric method, and greatly improves the sensitivity of the instrument. The key components of the system are imported, ensuring reliable performance of the entire machine. Suitable for determining the total nitrogen content of paraffin oil, diesel, gasoline, lubricating oil, fuel oil, liquefied gas, and natural gas, as well as other oil products, chemical raw materials, and finished products. It follows the standard SH/T 0657 for the determination of trace nitrogen in liquid petroleum hydrocarbons (oxidation combustion and chemiluminescence method, ASTM D5762-2017, SH/T0704, ASTM D4629, GB/T 17674 for the determination of nitrogen content in crude oil by boat injection chemiluminescence method).

Performance characteristics

Using pneumatic support to support the instrument cover, the internal structure of the instrument cover can be easily seen when opened.

Low and low content peaks have better shape and repeatability.

The total nitrogen content in the sample is rapidly measured by chemiluminescence method.

The application of high-precision data acquisition and computer technology provides reliable guarantees for data collection, control, and processing.

Technical parameters:

● Basic parameters: Sample types: liquid, solid, and gas

● Measurement method: chemiluminescence method

● Sample injection volume:

Solid sample: 1-20mg

Liquid sample: 5-20 μ L

Gas sample: 1-5mL

● Measurement range: 0.1-10000mg/L

● Measurement accuracy:

Concentration value (ppm) Injection volume (μ L) RSD(%)
0.1 20 25
5 10 10
50 10 5
100 10 3
5000 10 3

● Temperature control range: Room temperature ~ 1050 ℃

● Temperature control accuracy: ± 3 ℃

● Gas source requirements:

High purity argon gas: purity above 99.995%

High purity oxygen: purity above 99.995%

● Power supply: AC220V ± 22V 50Hz ± 0.5Hz 1500 W

● Dimensions: Host: 305 (W) × 460 (D) × 440 (H) mm

● Exterior weight: 20kg

● Temperature control size: 550 (W) × 460 (D) × 440 (H) mm

● Temperature controlled weight: 40kg

Basic parameters Sample types: liquid, solid, and gas
Measurement method chemiluminescence method
Sample injection volume

Solid sample: 1-20mg

Liquid sample: 5-20 μ L

Gas sample: 1-5mL

Measurement range 0.1-10000mg/L
Temp control range Room temp ~ 1050 ℃
Temp control accuracy ± 3 ℃
Gas source requirements

High purity argon gas: purity above 99.995%

High purity oxygen: purity above 99.995%

Power supply AC220V ± 22V 50Hz ± 0.5Hz 1500 W
Host size 305 (W) × 460 (D) × 440 (H) mm
Host weight 20kg
Temperature control size 550 (W) × 460 (D) × 440 (H) mm
Temperature controlled weight 40kg

Chemiluminescence Nitrogen Analyzer for Solid Liquid Gas Samples 0.1-10000mg/L 0

Note: The appearance pictures, dimensions, volume, and weight of the instrument are for reference only. If there are any updates to the instrument, there may be slight changes without prior notice.

Requirements for instrument completeness: host (data acquisition, control system), cracking furnace, automatic sampler (gas, liquid), computer operation software, etc.

Other optional items: computer, solid sampler, gas sampler (optional).

 

Shandong Shengtai Instrument Co., Ltd. provides the following quality assurance for the instruments sold to you:

----The provided instrument materials are brand new, meet national quality standards, and have a manufacturer's certificate of conformity;

----The materials and main components provided meet the technical requirements specified in the technical documentation;

----The overall quality assurance period of the equipment is one year (excluding normal wear and tear of vulnerable parts).

----We are responsible for free maintenance of any instrument quality issues that occur during the warranty period. Due to equipment malfunction caused by the user's responsibility, we are responsible for repairing and charging reasonable fees.

----Lifetime discounted supply of parts for equipment, and lifetime maintenance and repair of the entire machine.

----After the expiration of the warranty period, if the user needs maintenance and technical services, we will only charge a cost fee.

Chemiluminescence Nitrogen Analyzer for Solid Liquid Gas Samples 0.1-10000mg/L 1

Number Name Quantity Unit Specs Note
1 Host 1 Unit    
2 Injector 1 Unit    
3 Quartz tube 1 Piece   Install and carry
4 Standard sample 4 Box    
5 Quartz elbow 1 Piece    
6 Membrane dryer 1 Piece   Imported from Japan
7 Communication cable 1 Root    
8 Power line 2 Root    
9 Cracking furnace power supply 1 Root    
10 PTFE 8 Metre Φ3  
11 Silicone hose 20 cm Φ3  
12 Silicone hose 20 cm Φ5  
13 Large clamp 1 Piece    
14 Warranty Card Certificate of Conformity 1 Piece    
15 Instructions 1 Copy    
16 Half Moon Ceramic Cup 4 Piece    
17 Syringe 2 Piece   10ul
18 Fuse 2 Piece 2A  
19 Pneumatic pressure cap 4 Piece    
20 Thermocouple 1 Piece   S-type platinum rhodium platinum
21 Sample injection pad 50 Piece    